CBCT, CT and MRI file reference
DICOM export compatibility reference
Look up what a scanner or imaging program exports, which files to keep, and how to open them. This reference separates documented export options from recorded Ossidex sample tests. Unknown fields stay unknown.
26 software and scanner families; 17 distinct public-source test archives. Results apply to the listed samples and test dates, not every export from a vendor.
Export and sample lookup
| Vendor / software | Modality | Layout, DICOMDIR and viewer | Image file extensions | Transfer syntaxes seen | Multi-frame / Enhanced | Proprietary files: not standard DICOM | Tested public datasets | Ossidex test status | How to open, notes and sources |
|---|---|---|---|---|---|---|---|---|---|
| Planmeca Romexis | CBCT | One multi-frame DICOM file or a set of single-frame DICOM files; destination folder chosen during export. Folders: Unknown Documented export options; no public export sample counted. | Unknown | Unknown | Multi-frame: Unknown Multi-frame export is documented; an Enhanced SOP class has not been established here. | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. A Romexis Viewer package and a DICOM volume export are different choices. Exact folder names and private project extensions are unknown. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Carestream Dental CS 3D Imaging | CBCT | Axial DICOM slices in a selected output directory. Create DICOMDir is an export option. Folders: Unknown Documented volume and disc export options. | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. The volume export omits implants and annotations. Compression can be selected, but no transfer syntax from a tested CS 3D sample is recorded here. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Vatech Ez3D-i | CBCT | Local disk, USB or CD/DVD export with separately selectable DCM Files, Viewer and Project File. Folders: Unknown Documented export options; private clinic samples excluded from the public count. | Unknown | Unknown | Multi-frame: Unknown | Ez3D-i Project File | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Lossless is an export setting; the exact transfer syntax UID is unknown in this reference. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Dentsply Sirona GALILEOS / Sidexis | CBCT | The selected training sample contains numbered .dcm slices and an STL model. Sidexis DICOM examination export is documented separately. Folders: Unknown Selected public sample; not a universal vendor export layout. | .dcm | Explicit VR Little Endian | Multi-frame: Not observed in this sample | GALILEOS / GALAXIS volume package | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. The sample is a GALILEOS acquisition distributed for Blue Sky Plan training, not a validation of every Sidexis export setting. Sample redistribution terms are unknown. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| NewTom / Cefla NNT | CBCT | NNT documents DICOM export separately from sharing an NNT Viewer package. Folders: Unknown Documented options; exact folders and private formats are unknown. | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. No NNT-specific public import report is included. A viewer installer is not evidence that the image volume is present. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Imaging Sciences International / KaVo i-CAT | CBCT | The selected sample has DICOMDIR and extensionless image files such as DICOM/I0. Folders: Selected public sample; not a universal vendor export layout. | (none) | JPEG Extended (Process 2/4) | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. JPEG Extended is observed in the image files; DICOMDIR itself uses Explicit VR Little Endian. The sample does not establish Tx STUDIO project support. Sample redistribution terms are unknown. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| KaVo OP 3D Vision V17 | CBCT | The selected repackaged sample contains IMG0001.dcm and subsequent slices. Folders: Unknown Selected public sample; not a universal vendor export layout. | .dcm | Explicit VR Little Endian | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. One selected ScienceDB-derived demo archive is counted. Header model is 17-19DX; model attribution follows the sample manifest. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| J. Morita 3D Accuitomo / i-Dixel | CBCT | The selected OpenEar series contains .dcm slices without a Part 10 file-meta header. Folders: Selected public sample; not a universal vendor export layout. | .dcm | Unknown | Multi-frame: Not observed in this sample | i-Dixel / One Volume Viewer volume | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Transfer syntax is unknown: the inventory records raw datasets without file-meta transfer syntax. The public sample is a temporal-bone specimen, not an i-Dixel disc export. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| PaloDEx Group ORTHOPANTOMOGRAPH OP 3D | CBCT | Numbered .dcm slices plus CASEDATA/Workup.invwu in the selected course sample. Folders: Selected public sample; not a universal vendor export layout. | .dcm | Implicit VR Little Endian | Multi-frame: Not observed in this sample Enhanced CT SOP class, one slice per file; NumberOfFrames is absent. This is not a tested multi-frame Enhanced CT volume. | Unknown | 1 | Opens with limits | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Workup.invwu in this sample is an empty Basic Text SR DICOM object, not evidence of editable plan import. Do not classify all .invwu files from their extension. Sample redistribution terms are unknown. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Anatomage / Osteoid InVivo | CBCT, CT | Save As: Multi-file DICOM writes a folder of image slices. Save As Project is a separate operation. Folders: Unknown Documented workflow; no separate InVivo export test counted. | .dcm | Unknown | Multi-frame: Unknown | Invivo scan and workup Anatomage project Anatomage service output | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. The OP 3D row documents a separate course sample with an empty workup. It does not validate these proprietary formats. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Cybermed OnDemand3D | CBCT | Database Manager supports CD/USB sharing; request the standard DICOM images. Folders: Unknown Existing export guide; folder names and project extensions unknown. | Unknown | Unknown | Multi-frame: Unknown | OnDemand3D Project Viewer project | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| PointNix Software: unknown | CBCT | Unknown Folders: Unknown | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. The existing format guide names PointNix, but no model-specific export layout or public import report is established here. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Canon Classic and Enhanced MR | MRI | Public QA repository archives; scanner disc folder layout and bundled viewer are unknown. Folders: Unknown Selected QA collections, not a vendor media-export recipe. | Unknown | 1.2.840.10008.1.2.1 | Multi-frame: Yes, observed | Unknown | 2 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Historical development build, not a fresh test of the current App Store binary. No device-wide or model-wide guarantee. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| GE HealthCare MR QA collection | MRI | Public QA repository archives; scanner disc folder layout and bundled viewer are unknown. Folders: Unknown Selected QA collections, not a vendor media-export recipe. | Unknown | 1.2.840.10008.1.2.1 | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Historical development build, not a fresh test of the current App Store binary. No device-wide or model-wide guarantee. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Siemens Healthineers MR Mosaic and XA30 | MRI | Public QA repository archives; scanner disc folder layout and bundled viewer are unknown. Folders: Unknown Selected QA collections, not a vendor media-export recipe. | Unknown | 1.2.840.10008.1.2.1 | Multi-frame: Yes, observed | Unknown | 2 | Opens with limits | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. The October 16 Mosaic check covers the stored matrix only. Slice unpacking, MPR, measurements and temporal grouping were not validated by that check. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Toshiba MR QA collection | MRI | Public QA repository archives; scanner disc folder layout and bundled viewer are unknown. Folders: Unknown Selected QA collections, not a vendor media-export recipe. | Unknown | 1.2.840.10008.1.2.1 | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Historical development build, not a fresh test of the current App Store binary. No device-wide or model-wide guarantee. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| United Imaging MR QA collection | MRI | Public QA repository archives; scanner disc folder layout and bundled viewer are unknown. Folders: Unknown Selected QA collections, not a vendor media-export recipe. | Unknown | 1.2.840.10008.1.2.1 | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Historical development build, not a fresh test of the current App Store binary. No device-wide or model-wide guarantee. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Philips Achieva / Achieva dStream | MRI | The selected QA repository has image inputs under In/ and conversion references under Ref/. This is a research package, not a scanner disc. Folders: Selected public sample; not a universal vendor export layout. | (none), .dcm | Explicit VR Little Endian | Multi-frame: Yes, observed | Philips PAR/REC | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Classic MR and one Enhanced MR object are present. This import sweep does not validate quantitative Philips scaling or every frame. Sources and test scope
The JSON download identifies the exact test records and field evidence for this row. |
| Siemens Healthineers SOMATOM Confidence | CT | The selected public sample contains DICOMDIR with image files in nested directories. Folders: Unknown Selected public sample; not a universal vendor export layout. | (none) | Explicit VR Little Endian | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Only the identified public sample is counted. Other models, profiles and software versions remain untested here. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| GE HealthCare Revolution Apex | CT | The selected public sample contains numbered .dcm files. Repository packaging does not establish the scanner export layout. Folders: Unknown Selected public sample; not a universal vendor export layout. | .dcm | Explicit VR Little Endian | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Only the identified public sample is counted. Other models, profiles and software versions remain untested here. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Canon / Toshiba Aquilion Lightning | CT | The selected public sample contains numbered .dcm files. Repository packaging does not establish the scanner export layout. Folders: Unknown Selected public sample; not a universal vendor export layout. | .dcm | Explicit VR Little Endian | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Only the identified public sample is counted. Other models, profiles and software versions remain untested here. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Neusoft NeuViz 128 | CT | The selected public sample contains numbered .dcm files. Repository packaging does not establish the scanner export layout. Folders: Unknown Selected public sample; not a universal vendor export layout. | .dcm | Explicit VR Little Endian | Multi-frame: Not observed in this sample | Unknown | 1 | Opens | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Only the identified public sample is counted. Other models, profiles and software versions remain untested here. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Siemens Healthineers syngo fastView | CT, MRI | A Windows viewer can accompany images on CD/DVD and read the patient list from DICOMDIR. Folders: Unknown Documented media workflow; not a native Ossidex test or a scanner default. | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Exact software release date and current export profile are unknown. A media viewer workflow does not identify the scanner that acquired the images. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Philips DICOM Viewer 3.0 SP3 | CT, MRI | The conformance statement describes reading DICOMDIR and images from CD, DVD and USB. Folders: Unknown Documented media workflow; not a native Ossidex test or a scanner default. | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Exact software release date and current export profile are unknown. A media viewer workflow does not identify the scanner that acquired the images. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Intelerad InteleViewer PACS-5-3-1-P211 | CT, MRI | DICOMDIR plus patient/study/series subfolders. Repeated export adds numbered folders in DICOM. Include InteleViewer and Include Report are options. Folders: Documented media workflow; not a native Ossidex test or a scanner default. | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Exact software release date and current export profile are unknown. A media viewer workflow does not identify the scanner that acquired the images. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
| Fujifilm Synapse media export | CT, MRI | The documented media set places DICOMDIR at the root. A local export can use C:\SynapseMediaSets\SynYYYYMMDDHHMMSS. Folders: Documented media workflow; not a native Ossidex test or a scanner default. | Unknown | Unknown | Multi-frame: Unknown | Unknown | 0 | Not tested | Keep the complete image folder together. Import the folder or its ZIP in Ossidex on iPhone or iPad, then check the series and scroll through the images. Exact software release date and current export profile are unknown. A media viewer workflow does not identify the scanner that acquired the images. Sources and test scopeThe JSON download identifies the exact test records and field evidence for this row. |
No matching rows. Clear the filters to see all entries.
How we test and count samples
The Ossidex team links each row to a source document or a recorded native import result. The source JSON includes archive hashes, report hashes, dates and test scope. One prepared archive counts as one dataset; it may contain many studies or series. Public accessibility does not grant permission to redistribute image data.
The October 16, 2026 native check used Ossidex 1.12.0 (9) in an iPhone 17 Pro simulator with iOS 27.0. It imported seven complete archives and checked image availability, including 270 selected rasters. The separate October 12 web-core check compared 297 frames from 217 objects with pydicom. These checks have different scopes.
The November 2, 2026 corpus reports used the native importer and rendered one frame per series. They do not record the app build, device or source revision, so those fields remain unknown. The reference includes ten selected archives from these reports. It does not claim a fresh test of the current App Store version.
The earlier corpus milestone of 556 datasets is historical. Later pruning and additional samples changed the corpus; that number is not a vendor count and is not the denominator of this reference. No new app import tests were run for this update.
“Opens” means the identified sample passed its recorded import check. “Opens with limits” adds a limitation in the row. “Not tested” means no matching public import report is included. Neither sampled rendering nor a vendor document proves all-frame fidelity, measurement accuracy or transfer of editable plans. Ossidex is a viewer and planning aid, not a diagnostic device.
How to recognize and open an export
Keep the complete image folder or ZIP. DICOMDIR is an index; its referenced images must travel with it. Folder names vary: the DICOM standard assigns no meaning to names such as DICOM or IMAGES. A .dcm extension is useful but not required.
A Windows viewer on a disc is a separate program. Locate the image data instead of opening an EXE on an iPhone or iPad. A project, implant plan, surface mesh, PDF or screenshot is a different deliverable from a complete DICOM volume. Request standard DICOM from the sender when the required images are missing.
ZIP compression and DICOM transfer syntax are different layers. Multi-frame describes how frames are stored; Enhanced identifies an object structure. Neither is a codec. “Not observed” only describes the selected sample.
Vendor opening guides · DICOM · DCM files · DICOMDIR · Enhanced DICOM · Archives and disc images
Download, reuse and cite
Download compatibility.csv · Download compatibility.json
The original reference text and dataset are licensed under CC BY 4.0. Credit the Ossidex team, link to this page and the license, and indicate changes. External images, vendor documents, software and trademarks keep their own terms; no scan files are redistributed here.
Cite this page: The Ossidex team. DICOM export compatibility reference. Updated . https://ossidex.com/compatibility. CC BY 4.0.
Earlier test reports
The reports below are dated development snapshots, retained with their original limits and download URLs. Version comparisons and release statements describe the time of each check.
Details: Latest web decoding check: October 12, 2026
| Sample set | Selected objects | Compared frames | Enhanced objects | Objects with failures |
|---|---|---|---|---|
| Canon-Classic | 33 | 33 | 0 | 0 |
| Canon-Enhanced | 11 | 33 | 11 | 0 |
| GE | 87 | 87 | 0 | 0 |
| Siemens-Mosaic | 24 | 24 | 0 | 0 |
| Siemens-XA30 | 29 | 87 | 29 | 0 |
| Toshiba-5 | 15 | 15 | 0 | 0 |
| United-Imaging | 18 | 18 | 0 | 0 |
Headers of 13,222 archive objects were scanned. The first, middle and last object of each series were selected, then the first, middle and last frames where available. Independent pydicom comparisons covered 291 monochrome frames and 6 RGB frames: 8,787,072 calibrated scalar pixels and 31,104 RGB pixels, plus supplied geometry.
This ran the shipped WebAssembly core in Node on macOS, not the native app or a physical device. It does not establish browser GPU rendering, MPR or measurement accuracy. Siemens Mosaic means the raw stored matrix only; slice unpacking was not validated. Rendered output was checked for size and opacity, not an independent windowed-image match. These are software checks, not clinical validation.
Download the results: CSV · JSON.
JSON includes method, versions, input archive hashes and limitations. Original upstream revisions are unknown. The check ran on October 12; this summary was published on October 15. Earlier checks remain below for comparison.
Details: Native development check: October 16, 2026
A separate local development build of Ossidex 1.12.0 (9), on iPhone 17 Pro Simulator / iOS 27.0, imported all seven public archives: 13,222 objects. The native catalogue exposed 21,923 image frames; all produced pixel data or a rendered fallback. All 270 selected first/middle/last series images opened without errors. Seven tests passed, none failed or skipped.
| Sample set | Input objects | Decoded frames | Selected images | Image errors |
|---|---|---|---|---|
| Canon-Classic | 5720 | 5720 | 33 | 0 |
| Canon-Enhanced | 11 | 5720 | 33 | 0 |
| GE | 4360 | 4360 | 87 | 0 |
| Siemens-Mosaic | 48 | 48 | 24 | 0 |
| Siemens-XA30 | 95 | 3087 | 60 | 0 |
| Toshiba-5 | 2600 | 2600 | 15 | 0 |
| United-Imaging | 388 | 388 | 18 | 0 |
This is a development check of 1.12, not a test of the public App Store 1.11.2 binary or a physical phone. It checks import and image availability, not independent pixel accuracy, displayed proportions, MPR, measurements or temporal grouping. Siemens Mosaic covers the stored matrix only. The report retains three thread-priority warnings; performance and device lifecycle acceptance remain separate.
Known display issue from a separate check: in this 1.12 build, a public DICOM frame with non-square pixels appeared vertically compressed in classic 2D. A square-pixel control with the same values and physical dimensions preserved the proportions. A subsequent local fix restored matching proportions for both files and passed 20 focused geometry and display checks. The fix has not been released on the App Store; the seven availability tests above alone do not detect this issue.
Details: Web decoding check: October 2, 2026
| Sample set | Selected objects | First frames compared | Unsupported Enhanced | Maximum pixel-value difference |
|---|---|---|---|---|
| Canon-Classic | 33 | 33 | 0 | 0 |
| Canon-Enhanced | 11 | 0 | 11 | Not compared |
| GE | 87 | 87 | 0 | 0 |
| Siemens-Mosaic | 24 | 24 | 0 | 0 |
| Siemens-XA30 | 29 | 0 | 29 | Not compared |
| Toshiba-5 | 15 | 15 | 0 | 0 |
| United-Imaging | 18 | 18 | 0 | 0 |
Headers of 13,222 public archive objects were scanned. The test selected 217 objects: the first, middle and last from each series in archive-name order. For the 177 compatible images, it compared 8,124,672 DICOM-calibrated pixel values, plus available spacing, position and orientation. For selected multiframe objects, it attempted to decode the first, middle and last frame.
This historical check used the WebAssembly build distributed on October 2, 2026, in Node on macOS. It does not describe all capabilities of the current build or establish support for every scanner from a manufacturer. Pixel comparison covers the first frame of each selected object; it does not validate browser rendering, MPR, measurements or Siemens mosaic slice unpacking. The browser now supports compatible Enhanced frames with regular geometry; see current supported formats and limits.
Download web-check CSV · Download JSON with method, versions and limits
Details: Historical native-app reports
The seven archived development reports contain 270 image-presentation checks with no recorded errors. Published September 30, 2026, they are not a new test of the current app version or evidence of web-viewer support.
| Sample set | Public source | Studies | Reported decode checks | Presentation checks | Recorded errors |
|---|---|---|---|---|---|
| Canon / classic DICOM | dcm_qa_canon | 1 | 5,720 | 33 | 0 |
| Canon / Enhanced DICOM | dcm_qa_canon_enh | 1 | 5,720 | 33 | 0 |
| GE | dcm_qa_ge | 5 | 4,360 | 87 | 0 |
| Siemens / mosaic | dcm_qa_mosaic | 1 | 48 | 24 | 0 |
| Siemens / XA30 | dcm_qa_xa30 | 1 | 3,087 | 60 | 0 |
| Toshiba | dcm_qa_toshiba | 1 | 2,600 | 15 | 0 |
| United Imaging | dcm_qa_uih | 2 | 388 | 18 | 0 |
Details: What was checked
The test imported each archive, catalogued its series and exercised frame decoding. It requested the first, middle and last frame of each series through the app presentation path and recorded image dimensions and errors. Decode checks and presentation checks are different counts and must not be added together. These reports do not include the final outcome of the complete test run.
Details: How to read the limits
- These are archived reports, not a fresh test run on September 30.
- Original reports do not record the app build, device, exact test date or upstream revision. Those fields remain empty in the downloads.
- A nonempty rendered image does not establish pixel fidelity, measurement accuracy or clinical validation.
- Source links identify the upstream collections. Without the original revision, their current files may differ from the historical input.
- These datasets are separate from our dental export guides. A Romexis or Sidexis guide is not a test report for that scanner.
Details: Data and reproduction
Download CSV · Download JSON with method and limits
Downloads contain only aggregates, sources and report hashes, without images, patient identifiers or local paths. To run your own evaluation, choose a public sample from its source and record its revision, your device and Ossidex version; import the DICOM and compare slices with a known reference. Record opening, pixel appearance, geometry and tools separately.
Details: If your file does not open
Check that you received the complete study, not only DICOMDIR, a PDF or the disc’s .exe program. Keep the whole folder or ZIP. See opening problems and fixes and vendor export guides.
Vendor export guides and tested samples
Export instructions are separate from the sample results above. See Romexis, Sidexis, Carestream CS 3D, Vatech, OnDemand3D, NewTom NNT, i-CAT, Morita and Anatomage InVivo. The InVivo guide follows vendor documentation; it does not add a tested export to these results.
Sources
Related pages
What is a DICOM file? The medical imaging format explained
DICOM is the standard file format for medical images like CT, MRI and X-ray. What is inside a DICOM file, how studies and series work, and how to open one.
DCM file viewer: what a .dcm file is and how to open it on any device
What a .dcm file is, which DCM viewer to use on Windows, Mac, a browser or iPad, why one file shows one image, and how to convert DCM to JPG safely.
Enhanced multi-frame DICOM (CT and MR) on iPhone and iPad
Enhanced CT and MR store a whole series in one multi-frame DICOM file. How Ossidex reads per-frame geometry, calibration and 4D series on iPhone and iPad.
Open CBCT from any scanner
What is on a CBCT disc, what to export, and vendor-by-vendor instructions.
Ossidex videos: CBCT, MRI, MPR and dental arch
Watch Ossidex how-to videos for scan folders, DICOMDIR, download links and implant planning, alongside recorded CBCT, MRI, MPR and dental arch demos.